Tuned Mass Dampers for the Slussen Footbridge in Stockholm

Eight Tuned Mass Dampers (TMDs) have been integrated into the new Slussen Footbridge in Stockholm to reduce vibrations and improve pedestrian comfort. Installed within the bridge’s steel structure, the dampers are designed to control resonance modes across the different spans of the bridge.

“It’s been 10 years since my colleague Anders and I visited ELU Konsult to discuss TMDs for this bridge. It was interesting to finally follow the construction on site in Stockholm.”

– Svante Hägerstrand,
CEO, Vibratec Akustikprodukter

Vibratecs CEO Svante Hägerstrand at Tuned Mass Damper project in Slussen
Svante Hägerstrand visiting the Slussen Footbridge during the installation and commissioning phase of the Tuned Mass Dampers.

The Slussen Footbridge is one of Stockholm’s most prominent infrastructure projects. To control structural vibrations and ensure a comfortable experience for pedestrians, eight Tuned Mass Dampers (TMDs) have been integrated into the bridge’s steel structure.

Each TMD weighs 3.5 tonnes and has been carefully tuned to dampen the resonance modes of the different bridge spans within the frequency range of 1.5–2.5 Hz. The dampers are positioned inside the steel sections of the bridge, providing an effective vibration control solution while remaining completely hidden from view.

The final on-site tuning of the TMDs will be carried out once the top layers of concrete and asphalt have been added. This ensures that the damping system is optimally adjusted to the bridge’s final weight and dynamic characteristics.

Vibratec would like to thank GERB for their excellent support and quick delivery, as well as Skanska for the opportunity to contribute to this exciting project.

Image of Tuned Mass Damper from Vibratec
Tuned Mass Damper from Vibratec
Image of Footbridge in Slussen
Image of Slussen Footbridge
Image of Footbridge in Slussen

Interested in Vibration Control Solutions for Infrastructure Projects?

N’hésitez pas à nous contacter pour plus d’informations

Contactez nous

Image de Årstabron
  • Infrastructure
  • Construction

Amortissement des couches contraint sur un vieux pont en acier

Vibratec réduit le bruit sur le pont Årsta, dans le centre de Stockholm. En utilisant une technique appelée "constrained Layer Dampening" (CLD). Le bruit est réduit de 6 dB.

Panneaux d'absorption acoustique Vibratec Reapor pour l'intérieur et l'extérieur.
  • Construction
  • Infrastructure
  • Industrie

Reapor® - L'absorbeur de son pour les environnements difficiles !

Reapor® est un absorbeur acoustique écologique fabriqué à partir de verre recyclé, adapté aux applications intérieures et extérieures.

Ersta Sjukhus
  • Construction

Des performances silencieuses dans des lieux exigeants

Deux projets de référence Vibratec à Stockholm sont maintenant présentés dans des études de cas par notre fournisseur REGUPOL : Ersta Hospital à Södermalm et Lydiahemmet à Farsta strand.

  • Infrastructure

Étude de cas : Amortisseurs à masse ajustée pour une passerelle piétonne à Malmö

Lors de la conception structurelle de la passerelle piétonne de Bagers Plats à Malmö, il est devenu évident qu'elle nécessiterait un TMD, car la verticale la plus basse a été calculée à 1,85 Hz. Vibratec a conçu une solution TMD : au total, 2 TMD d'une masse vibrante de 340 kg chacun ont été installés dans la section médiane du...