Regufoam Vibration Isolation
Regufoam 190
Product Characteristics
Sheets, strips or pads
On request: Die-cutting, water-jet cutting, self-adhesive versions possible
Continuous static load
0.018 N/mm²
Continuous and variable loads/operating load range
0 to 0.028 N/mm²
Peak loads (rare, short-term loads)
0.8 N/mm²
Standard forms of delivery, ex warehouse
Rolls
Thickness: 12.5 and 25 mm are standard, and regularly available off the shelf. Special thicknesses on request
Length: 5000 mm, special lengths available on request
Width: 1500 mm
On request we can tailer to your needs and produce 75, 50, 37.5, 25, 12.5, 6 mm all the way down to 2 mm thicknesses.
Technical Specifications








regufoam-190-specifications.xlsx
Regufoam 190
Physical property | Norm | Result | Comment |
Static modulus of elasticity | Based on EN 826 | 0.10 - 0.25 N/mm2 | Tangential modulus, see figure “modulus of elasticity” |
Dynamic modulus of elasticity | Based on DIN 53513 | 0.25 - 0.55 N/mm2 | Depending on frequency, load and thickness, see fi gure “dynamic stiffness“ |
Mechanical loss factor | DIN 53513 | 0.25 | Load-, amplitude- and frequency-dependent |
Compression set | Based on DIN EN ISO 1856 | 2.0 % | Measured 30 minutes after decompression with 50 % deformation / 23 °C after 72 hrs |
Tensile strength | Based on DIN EN ISO 1798 | 0.4 N/mm2 | |
Elongation at break | Based on DIN EN ISO 1798 | 220% | |
Tear resistance | Based on DIN ISO 34-1 | 2.0 N/mm | |
Fire behaviour | DIN 4102 | B2 | |
DIN EN 13501-1 | E | ||
Sliding friction | REGUPOL-laboratory | 0.7 | Steel (dry) |
REGUPOL-laboratory | 0.8 | Concrete (dry) | |
Compression hardness | Based on DIN EN ISO 3386-2 | 22 kPa | Compressive stress at 25 % deformation test specimen h = 25 mm |
Rebound elasticity | Based on DIN EN ISO 8307 | 35% | dependent on thickness, test specimen h = 25 mm |
Force reduction | DIN EN 14904 | 61% | dependent on thickness, test specimen h = 25 mm |