Tuned Mass Dampers for the Slussen Footbridge in Stockholm

Eight Tuned Mass Dampers (TMDs) have been integrated into the new Slussen Footbridge in Stockholm to reduce vibrations and improve pedestrian comfort. Installed within the bridge’s steel structure, the dampers are designed to control resonance modes across the different spans of the bridge.

“It’s been 10 years since my colleague Anders and I visited ELU Konsult to discuss TMDs for this bridge. It was interesting to finally follow the construction on site in Stockholm.”

– Svante Hägerstrand,
CEO, Vibratec Akustikprodukter

Vibratecs CEO Svante Hägerstrand at Tuned Mass Damper project in Slussen
Svante Hägerstrand visiting the Slussen Footbridge during the installation and commissioning phase of the Tuned Mass Dampers.

The Slussen Footbridge is one of Stockholm’s most prominent infrastructure projects. To control structural vibrations and ensure a comfortable experience for pedestrians, eight Tuned Mass Dampers (TMDs) have been integrated into the bridge’s steel structure.

Each TMD weighs 3.5 tonnes and has been carefully tuned to dampen the resonance modes of the different bridge spans within the frequency range of 1.5–2.5 Hz. The dampers are positioned inside the steel sections of the bridge, providing an effective vibration control solution while remaining completely hidden from view.

The final on-site tuning of the TMDs will be carried out once the top layers of concrete and asphalt have been added. This ensures that the damping system is optimally adjusted to the bridge’s final weight and dynamic characteristics.

Vibratec would like to thank GERB for their excellent support and quick delivery, as well as Skanska for the opportunity to contribute to this exciting project.

Image of Tuned Mass Damper from Vibratec
Tuned Mass Damper from Vibratec
Image of Footbridge in Slussen
Image of Slussen Footbridge
Image of Footbridge in Slussen

Interested in Vibration Control Solutions for Infrastructure Projects?

Kontakta oss gärna för mer information

Kontakta oss

Bild av Årstabron
  • Infrastruktur
  • Bygg

Constrained layer damping på gammal stålbro

Vibratec minskar bullret på Årstabron i centrala Stockholm. Med hjälp av en teknik som kallas Constrained Layer Dampening (CLD). Bullret sänktes med 6 dB.

Vibratec Reapor ljudabsorberande paneler för inomhus- och utomhusbruk.
  • Bygg
  • Infrastruktur
  • Industriell

Reapor® - Ljudabsorbenten för utmanande miljöer!

Reapor® är en miljövänlig ljudabsorbent tillverkad av återvunnet glas, lämplig för både inomhus- och utomhusbruk.

Ersta Sjukhus
  • Bygg

Tyst prestanda i krävande miljöer

Två av Vibratecs referensprojekt i Stockholm presenteras nu i fallstudier av vår leverantör REGUPOL: Ersta sjukhus på Södermalm och Lydiahemmet i Farsta strand.

  • Infrastruktur

Fallstudie: Tuned Mass Dampers för gångbro i Malmö

Under konstruktionen av gångbron vid Bagers Plats i Malmö blev det uppenbart att den skulle behöva en TMD, eftersom den lägsta vertikalen beräknades till 1,85 Hz.Vibratec utformade en TMD-lösning: totalt 2 TMD:er med en vibrationsmassa på vardera 340 kg installerades i mittsektionen av gångbron...